Thomas Billy 2 months ago in Melee updated by Marti (Lead Developer) 2 months ago 1

The on air condition is not registering for the in air attacks i have set up. I tried them each alone thinking the system did not support combos in the air but that was not the issue. I also took the attacks off of a condition and placed them on a regular on key down trigger which thankfully was not the issue. See problem here

Unity version:
2019.4.2
Game Creator version:
1.19
+1
Answered

There is probably an entry of the Combo Creator without any condition that detects the A key higher on the list. Remember that the Combo Creator evaluates from top to bottom and choses the first entry that evaluates as positives.

As a rule of thumb, all conditions (which are more restrictive) should be set higher in the list and the ones that don't have conditions, at the bottom.